基本信息

孙涛    副研究员    中国科学院深圳先进技术研究院
电子邮件: tao.sun@siat.ac.cn
通信地址: 深圳市学苑大道1068号
邮政编码:518055 

网站:colddie.github.io

招生信息

   
招生专业
083100-生物医学工程
081203-计算机应用技术
082703-核技术及应用
招生方向
核医学成像技术
CT成像技术

发表文章


1.       Sun T, Wu Y, Bai Y, Wang Z, Shen C, Wang W, Li C, Hu Z, Liang D, Liu X, Zheng H, Yang Y, Wang M. "An iterative image-based motion compensation method for dynamic brain PET imaging", Physics in Medicine & Biology, Accepted, 2021.

2.       Sun T, Fulton R, Hu Z, Sutiono C,Liang D,Zheng H, "Inferring CT perfusion parameters and their uncertainties using a Bayesian approach", Quantitative Imaging in Medicine and Surgery, Accepted, 2021.   

3.       Sun T, Jacobs R, Pauwels Ruben J, Tijskens E, Fulton Roger R, Nuyts, J. “A motion correction approach for oral and maxillofacial cone-beam CT imaging”, Physics in Medicine & Biology, (66): 125008, 2021.

4.       Zhang C, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y, Liu Z. “A thick semi-monolithic scintillator detector for clinical PET scanner.” Physics in Medicine & Biology, (66): 065023, 2021.

5.       Yaping Wu, Tao Feng, Yu Shen, Fangfang Fu, Nan Meng, Xiaochen Li, Tianyi Xu, Sun T, Fengyun Gu, Qi Wu, Yun Zhou, Hui Han, Yan Bai, Meiyun Wang. "Total-body Parametric Imaging using the Patlak Model: Feasibility of reduced scan time", Medical Physics, Accepted, 2021.

6.       Zhang C, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y. "Physical and Imaging Performance of SIAT aPET under Different Energy Windows and Timing Windows", Medical Physics, Accepted, 2021.

7.       Ming N, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y. “Ultra-high resolution depth encoding small animal PET detectors using GAGG and LYSO crystal arrays”, Medical Physics, Accepted, 2021.

8.       M Alpert, Matthieu Galarneau, Sally Kim, Petibon Y, Sun T, M Ramos-Torres, Normandin Marc, El Fakhri Georges. “In-Vivo Imaging of Mitochondrial Depolarization of Myocardium with Positron Emission Tomography and a Proton Gradient Uncoupler” Frontiers in Physiology, vol.46, no.11, 2020.

9.       Sun T, Petibon Y, Han PK, Ma C, Kim SJW, Alpert NM, El Fakhri G, Ouyang J, “Body motion detection and correction using list-mode data for cardiac PET,” Medical Physics, Sep 11, 46(11), 2019.

10.     Petibon Y, Sun T*, Han PK, Ma C, El Fakhri G and Ouyang J,” MR-based motion correction of cardiac PET: Evaluation in Static and Dynamic Imaging of Myocardial Glucose Consumption,” Physics in Medicine & Biology, Oct 4;64(19):195009, 2019 (co-first). 

会议报告

1.     Sun T, Wang Y, Hu Z, Li C, Yang Y, “Tracer kinetics driven motion correction in dynamic PET imaging”, 2021 Society of Nuclear Medicine & Molecular Imaging Meeting, Washington, DC, 2021.

2.     Sun T, Wang Y, Hu Z, Yang Y, Li C, “Peak-Clearance-Rate as index for detection of Alzheimer’s Disease using 11C-PiB PET imaging”, Society of Nuclear Medicine & Molecular Imaging Meeting, Washington, DC, 2021.

3.     Sang Z, Kuang Z, Lee J, Wang X, Ren N, Wu S, Gao D, Zeng T, Liu Z, Sun T, Hu Z, Li Y, Yang Y, “MRI Compatibility Measurements of SIAT aPET”, 2021 Society of Nuclear Medicine & Molecular Imaging Meeting, Washington, DC, 2021.

4.     Chen Z, Li C, Sun T, WANG Y, Liang D, Liu X, Yang Y, Zheng H, Hu Z, Li K, Cheng Z, Cui X, Duan Y,” Iterative method for the calculation of parametric images from dynamic brain PET images”, 2021 Society of Nuclear Medicine & Molecular Imaging Meeting, Washington, DC, 2021.

5.     Kuang Z, Sang Z, Wang X, Gao D, Ren N, Wu S, Zeng T, Niu M, Cong L, Liu Z, Sun T, Hu Z, Du J, Yang Y,” Design and Development of an MRI Compatible Human Brain PET Scanner by Using Dual-ended Readout Detectors”, 2021 Society of Nuclear Medicine & Molecular Imaging Meeting, Washington, DC, 2021.

6.     Sun T, Fulton R, "A Bayesian approach for CT perfusion parameters estimation with imperfect measurement", SPIE Medical Imaging Conference, vol.11600, pp.1160007, 2021.

7.     Sun T, "Peak-Decay-Rate as index for detection of Alzheimer’s Disease using 11C-PiB PET imaging", SPIE Medical Imaging Conference, vol.11595, pp. 1159508, 2021.

8.     Sun T, Fulton R, "Inferring CT perfusion parameters and their uncertainties using a Bayesian approach", The Fourth International Symposium on Image Computing and Digital Medicine, 2020.

9.     Sun T, Becker JA, Lois C, Johnson K, El Fakhri G, Ouyang J. “Time-of-flight List-mode based motion correction for 18F-MK6240 PET imaging”, Society of Nuclear Medicine & Molecular Imaging Meeting 2020.

10.  Sun T, Petibon Y, Han PK, Ma C, El Fakhri G and Ouyang J, “MR-based motion correction of cardiac PET: Evaluation in Static and Dynamic Imaging of Myocardial Glucose Consumption,” presented at Society of Nuclear Medicine & Molecular Imaging Meeting 2019.

11.  Kim SJW, Pelletier-Galarneau M, Petibon Y, Sun T, Martineau P, Normandin M, El Fakhri G, Alpert NM, “Measurement of Myocardial Membrane Potential by Primed Constant Infusion,” presented at Society of Nuclear Medicine & Molecular Imaging Meeting 2019.


招聘招生


医学影像方向常年招聘客座学生,有意请联系tao.sun@siat.ac.cn